1. Home
  2. C. Communications and Settings
  3. C11. Reset and Restart settings.

C11. Reset and Restart settings.

Reading Time: < 1 minute - Video Time:

VPStudio 2 preparation

VPStudio 2 in-depth Software

 

1. Introduction

In this chapter we will cover:

  • What the reset and restart options cover.
  • How to perform these actions via the Transmitter/display or VPStudio 2.

2. Definitions

Factory reset: resets the device back to the factory default settings. This includes deleting all data log sessions and it can be performed via:

Transmitter/display
VPStudio 

Restart: restarts the flow meter. It can be performed via:

Transmitter
Display

3. Adjusting manually via the Transmitter / display

3.1 Factory reset

Go to the Menu >> Factory reset.

Confirm the reset by pressing the up and down button simultaneously.

Transmitter factory reset

Warning: a factory reset will remove all of the recorded data from the device!

2.2.  Restart

Go to the Menu >> Restart.
Go to the Menu >> Advanced >> Reset .

Press “Enter” to start to restart the device.

Transmitter - Restart

The reset option is also required when updating the display firmware.

4. Adjusting via VPStudio 2 software

Factory reset only, VPFlowScope M only.

In VPStudio 2 unfold the settings menu of the flow meter and select the “Settings” option.

 

Go to the last tab on the page “Miscellaneous”:

  1. At Factory reset: press “Reset device to factory settings”. 
  2. Then press “Save”.

5. Adjusting via the Internal Web Server

A factory reset is not possible via the Internal Web Server, in order to perform a factory reset use the Transmitter or make use of VPStudio 2.

6. Next step

Now that you finished the communications settings the next step is the mechanical installation of the flow meter.

Updated on July 29, 2020